docs(network): drop SFP-to-RJ45 module from Lite-8 ↔ CRS309 link
The CRS309's GbE RJ45 port is a full switchport that also accepts 802.3at PoE-in, so a single Cat6 from a Lite-8 PoE+ port to the CRS309 GbE port carries both the 1G trunk and the power. §7.4 already described this; §7.3, the link table, the topology mermaid, the migration sequence, the PoE budget, and the BoM contradicted it by assuming a 1G SFP-to-RJ45 module on a CRS309 SFP+ cage (physically impossible to also pass PoE). Aligned all of the above with the RJ45-to-RJ45 design and removed the UACC-CM-RJ45-1G line from the shopping list.
This commit is contained in:
parent
649325e0fb
commit
928de859a4
1 changed files with 11 additions and 14 deletions
|
|
@ -94,7 +94,7 @@ graph TD
|
|||
MSA2 -->|"10G SFP+ DAC"| CRS["MikroTik CRS309-1G-8S+IN<br/>10G SFP+ core (PoE-in)"]
|
||||
|
||||
CRS -->|"10G SFP+ DAC"| UNAS["UNAS Pro"]
|
||||
CRS -->|"1G SFP-to-RJ45 + PoE-in"| LITE["UB USW Lite 8 PoE<br/>Access + PoE source"]
|
||||
CRS -->|"1G RJ45 trunk + PoE-in (single Cat6)"| LITE["UB USW Lite 8 PoE<br/>Access + PoE source"]
|
||||
|
||||
LITE -->|"PoE+"| AP["UniFi U6-LR AP"]
|
||||
LITE -->|"PoE+"| RPI["Raspberry Pi 4B<br/>Technitium DNS"]
|
||||
|
|
@ -135,7 +135,7 @@ Notes:
|
|||
| ONT ↔ MS-A2 (WAN) | 1G / 2.5G | Terminates on an MS-A2 RJ45 NIC; pfSense VM owns the interface (PCIe passthrough) |
|
||||
| MS-A2 ↔ MikroTik CRS309 | 10G | 10Gtek SFP+ DAC, MS-A2 SFP+ → CRS309 SFP+ |
|
||||
| MikroTik CRS309 ↔ UniFi NAS Pro | 10G | 10Gtek SFP+ DAC into NAS Pro's native SFP+ port (no module) |
|
||||
| MikroTik CRS309 ↔ USW-Lite-8-PoE | 1G | 1G SFP-to-RJ45 module on CRS309; same cable also delivers PoE-in to power the CRS309 |
|
||||
| MikroTik CRS309 ↔ USW-Lite-8-PoE | 1G | Lite-8 PoE+ RJ45 → CRS309 GbE RJ45 (no SFP module); same Cat6 carries the 1G trunk and 802.3at PoE-in |
|
||||
| Lite-8 ↔ U6-LR | 1G | AP uplink class is 1G, powered via PoE+ |
|
||||
| Lite-8 ↔ SLZB-06U | 1G | Powered via PoE from the Lite-8 |
|
||||
| Lite-8 ↔ Wyse 5070 | 1G | Lite-8 port 7 |
|
||||
|
|
@ -180,13 +180,11 @@ Mount these into the relevant Proxmox VMs. Update `DOCKERSTORAGEDIR` / `DOCKERCO
|
|||
- Same-VLAN traffic stays switched at L2 on the CRS309 and avoids the pfSense routing path entirely.
|
||||
- Cross-VLAN bulk transfer hairpins through the pfSense VM and is constrained by VM CPU + any inspection rules.
|
||||
|
||||
### 7.3 MikroTik CRS309 is SFP+ only — module choices and thermal
|
||||
- CRS309-1G-8S+IN has 8× SFP+ cages and 1× GbE RJ45 (management + PoE-in). No 10G RJ45 ports.
|
||||
- For the Lite-8 uplink use a **1G SFP-to-RJ45 module**, not a 10G copper module.
|
||||
- The Lite-8 is 1G — a 10G copper module negotiates at 1G anyway (no benefit on this link).
|
||||
- 10GBASE-T copper SFP+ modules dissipate ~2-2.5W idle and 4-5W under load. The CRS309 is fanless aluminium and MikroTik explicitly warns about 10GBASE-T thermal load.
|
||||
- A 1G SFP-to-RJ45 module is well under 1W and runs cool.
|
||||
- If a future access switch with native SFP+ replaces the Lite-8, swap the module then.
|
||||
### 7.3 MikroTik CRS309 port layout and SFP+ thermal
|
||||
- CRS309-1G-8S+IN has 8× SFP+ cages and 1× GbE RJ45 (full switchport, also accepts PoE-in). No 10G RJ45 ports.
|
||||
- The Lite-8 uplink lands on the CRS309's GbE RJ45 port directly (Cat6 RJ45-to-RJ45) — same port also receives PoE-in (see §7.4). **No SFP-to-RJ45 module is used or needed for this build.**
|
||||
- Thermal note for any future SFP+ copper module: 10GBASE-T copper SFP+ modules dissipate ~2-2.5W idle and 4-5W under load. The CRS309 is fanless aluminium and MikroTik explicitly warns about 10GBASE-T thermal load — relevant if §11.2's "mGig copper module" path is ever taken.
|
||||
- If a future access switch with native SFP+ replaces the Lite-8, move the uplink to an SFP+ cage and free the GbE port for management/PoE-in only.
|
||||
|
||||
### 7.4 Power the CRS309 via PoE-in from the Lite-8 (no DC PSU)
|
||||
- CRS309 accepts 18-57V PoE-in on its GbE RJ45 — the same port used as the Lite-8 uplink.
|
||||
|
|
@ -200,7 +198,7 @@ USW-Lite-8-PoE has **4× PoE+ (802.3at) ports with a 52 W total PoE budget**. Po
|
|||
|---|---:|---|
|
||||
| UniFi U6-LR AP | ~12.95 W | 802.3af class |
|
||||
| Raspberry Pi 4B + PoE HAT | ~5-7 W | Typical / peak |
|
||||
| MikroTik CRS309-1G-8S+IN | ~10-12 W | Includes 2× SFP+ DAC + 1× SFP-RJ45 1G module populated |
|
||||
| MikroTik CRS309-1G-8S+IN | ~9-11 W | 2× SFP+ DAC populated; GbE RJ45 used as Lite-8 uplink + PoE-in |
|
||||
| SMLIGHT SLZB-06U | ~2-3 W | 802.3af class |
|
||||
| **Total** | **~30-35 W** | Of 52 W budget |
|
||||
|
||||
|
|
@ -264,7 +262,7 @@ Optional use for the 3rd DAC: a second MS-A2 ↔ CRS309 link as **LACP** for red
|
|||
2. Validate WAN cutover from Netgate 1100 to MS-A2 pfSense VM during a maintenance window. Leave Netgate cabled but unplugged for fast rollback.
|
||||
3. Rack the MikroTik CRS309. Power it via PoE-in from a Lite-8 PoE+ port (single Cat6 carries trunk + power).
|
||||
4. Bring up the 10G DAC between MS-A2 and CRS309. Verify 10G full duplex on both ends.
|
||||
5. Migrate the Lite-8 uplink onto the CRS309 (1G SFP-RJ45 module). Confirm VLANs and AP/Pi adoption still work.
|
||||
5. Migrate the Lite-8 uplink onto the CRS309's GbE RJ45 port (same Cat6 that powers it via PoE-in). Confirm VLANs and AP/Pi adoption still work.
|
||||
6. Rack the UniFi NAS Pro 2U. Connect the second 10G DAC to the CRS309. Validate 10G link.
|
||||
7. Install UniFi Network Application on the NAS Pro. Adopt the Lite-8 and U6-LR.
|
||||
8. Provision UNAS Pro NFS shares (`media`, `downloads`, `appdata-backups`).
|
||||
|
|
@ -460,10 +458,9 @@ Core subtotal: **TBD**
|
|||
| Item | Qty | Unit Price (incl. VAT) | Subtotal | Buy link |
|
||||
|---|---:|---:|---:|---|
|
||||
| 10Gtek SFP+ Passive DAC, 1m (`XDACBL1M`-compatible) | 3 | Already owned | — | — |
|
||||
| Ubiquiti SFP to RJ45 1G (`UACC-CM-RJ45-1G`) — for Lite-8 uplink | 1 | R404 | R404 | [GeeWiz](https://www.geewiz.co.za/new-items/481072-ubiquiti-125g-sfp-to-rj45-gigabit-ethernet-module-uacc-cm-rj45-1g.html) |
|
||||
| Cat6 patch lead (PoE-in + uplink to CRS309) | 1 | Already owned / negligible | — | — |
|
||||
| Cat6 patch lead (PoE-in + 1G uplink, Lite-8 PoE+ → CRS309 GbE) | 1 | Already owned / negligible | — | — |
|
||||
|
||||
Accessories subtotal: **R404** (DACs already in hand)
|
||||
Accessories subtotal: **R0** (DACs and Cat6 patch already in hand; no SFP-to-RJ45 module required — Lite-8 ↔ CRS309 is RJ45-to-RJ45)
|
||||
|
||||
### 13.3 Estimated total
|
||||
**Grand total (incl. VAT): TBD** — fill in once MS-A2, CRS309, and UNAS-Pro quotes are confirmed.
|
||||
|
|
|
|||